19“ Master clock with Ethernet Interface, modern operation via network

Type MPU-R-TC204P-NET
Technical specifications
  • Two independent slave clock lines
  • Connection of up to 2x 50 impulse controlled or up to 2x 50 self-correcting Time Code slave clocks (max. output current 0.5 A each line)
  • Polarised 24 V DC outputs for minutes-, ½ minutes - or seconds impulses respectively time code for operation of self-correcting and self-setting slave clocks
  • Mixed operation of slave clocks and self-correcting clocks possible
  • Impulse length adjustable
  • Impulse to break rate programmable
  • Automatic adjustment of slave clocks after mains failure
  • Electronic impulse memory for min. 5 years
  • Automatic summer-/winter daylight-saving time programmable
  • Everlasting calendar
  • Automatic free programmable holiday calendar with or without holidays depending on Easter
  • Electronic short-circuit protection
  • Electronic low voltage cut-off (18 V)
  • Multi-functional display (LCD) with two lines (20 characters per line, digit height 6 mm)
  • Indication of weekday, hours, minutes, seconds, date, summer-/winter time and DCF reception

Synchronisation through:

  • DCF-77 (for time and summer-/winter time changes)
  • GPS system (for time and summer-/winter time changes)
  • 24 V DC polarised minute impulses (master/slave operation)
  • Text message on display in case of missing DCF/GPS synchronisation after adjustable time
  • Error text message in case of short-circuit on a slave line
  • Accuracy ±0.1 s/day at 25 °C (without DCF synchro nisation)

Signalling device

  • Four potential free switchover contacts
  • 99 day programs with max. 99 program steps each
  • Period table with 99 program lines
  • Copy function for day programs
  • Switching times per second
  • On/Off- and timer-functions with 1 s … 59 min. run time
  • 32 different timer lengths programmable
  • Checking of programming via display
  • Single-, partial- and complete deletion of programs
  • Program memory for 99 day programs with totally 9801 (=99x99) program steps
  • Alarm relay function: The relay switches off in case of an alarm condition (short-circuit on slave line or missing DCF/GPS synchronisation).
  • Relay function depending on summer-/winter time status: The relay is only active either at current summer time or winter time.
  • Contact rating 250 V / 4 A (ohmic load)

NTP-Interface

  • The master clock is fitted with a 10/100 Base-T Ethernet Interface, which enables to act as NTP time server in a TCP/IP v4 network (RJ45 connection)
  • NTP (Network Time Protocol) protocol for synchronisation of computers in a PC network = international standard for PC time transmission in internet
  • NTP is also used in smaller networks (LAN) for synchronisation of PC server and PC work stations
  • Alarm messages per e-mail at NTP errors possible
  • Input (RJ45) for use of master clock as net client in a TCP/IP network
  • This interface supports following protocols:
  • NTP and SNTP:
  • Network Time Protocol (NTP) v2, v3 and v4 in Unicast, Broadcast and Multicast
  • Simple Network Time Protocol (SNTP) v3 and v4 in Unicast, Broadcast and Multicast
  • Network accuracy:
  • Synchronisation typically within 10ms…100ms of MPU-TC-NET time base, depending on network delay and jitter (NTP)
  • Comfortable remote control of complete master clock via web interface:
  • no additional software necessary, handling via standard web browser possible
  • Export of master clock configuration as file
  • Re-establishment at any time
  • Selection of data options which shall be imported
  • Alarm message by e-mail:
  • at synchronisation failure
  • at short-circuit of slave lines
  • Supervision of a 24VDC alarm input
  • Software-Update if necessary
  • Remote maintenance and -programming

Technical specifications:

  • Power supply: 110…240 V AC, 50/60 Hz
  • Current consumption: < 0.4 A @ 230 V AC
  • Data storage: > 1 year (the battery stores data during mains failure)
  • Case: 19” rack, 1 HE
  • Width 483 mm x Depth 245 mm x Height 44 mm
  • Weight: approx. 2 kg
  • Operating temperature: 0 … 50 ºC
  • Rel. humidity: 0 % to 90 % (non-condensing)

Options:

  • DCF-ANT02: DCF-77 radio synchronisation antenna
  • GPS-ANT8: GPS reception antenna with DCF output
  • RS232/RS485: Serial output
Description
Productfile MPU-R-TC204P-NET_master_clock_19inch.pdf
Diagramfile

This website uses cookies

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookie Policy.

Some cookies on this site are essential, and the site won't work as expected without them. These cookies are set when you submit a form, login or interact with the site by doing something that goes beyond clicking on simple links.

We also use some non-essential cookies to anonymously track visitors or enhance your experience of the site. If you're not happy with this, we won't set these cookies but some nice features of the site may be unavailable.